Grid Charger
Grid charger owners and location, as well as some service links for hybrid services
Grid charger code V3.0 manual
Understanding the charging and balancing process
Pack discharger
SOC reset device
Insight Battery pack lifter
Grid charger test adapters
Reprogramming the charger
Installing the Genesis One Universal grid charger in an Insight
Installing the Genesis One Universal grid charger in a First Gen Civic
Harness options
The Universal Grid Charger
MIMA Pack Whack and rebalancing the battery
Battery pack rebalancing?
Building the Solar HV charger/rebalancer
Building the HV probe for the + attachment
failure mode #1 Shorted Cell and the cell Zapper fix?
current indicator
Equilization test #1
fast pack rebalancing 101
Getting better signals
Grid charger/Balancer 1
How do I test the sticks to determine which I need to be replaced
Hybrid Battery Repair
IMA battery smart discharger
Looking better on the second cycle
more tuning of the controller/ Datalogger
Not really rebalanced just changed????
Overnight two stage charger
pack rebalancing test 1
Rebalancing?
Refining the tester
Replacement for 1 Watt LED
Insight Battery pack Solar charger/rebalancer
Subpacks 1-8
Subpack tested first high current run
Subpack tester first test
The HV panels can bend and will shock the S**T out of you
universal dual stage grid charger
What is wrong with the subpacks?
Mikes Insight
EV Insight with a Prius heart
Grid charger Operating Instructions V1.2
Designing a PHEV system for the Civics, Insight 1 and 2 ------------Micro V-Buck PHEV
Doug's V-Boost
Randall's Insight
Paul's Adventures in alternative evergy
Western Washington University X-Prize car
BlueBird1
Finding The Best Hybrid Mix
E-wheel for any vehicle

Rebalancing?

Rebalancing?
could this be proof of rebalancing?

I had to go out for a long trip, so I set up one of the 350ma CC supplies and put it across subpack #9.
9.6 hours later, it looks from the trace that the cells that were unbalanced worked their way up to the same level as the better cells. After 3 hours, just before I left for the trip that trend upwards had just begun to happen.
I will let it soak for a few more hours, and tomorrow after a night of settling we will see if the cells truly rebalanced.
Notice on the top photo how unbalanced the initial cell voltages were when the charge first started. Some unbalance was still evident after the initial quick charge.
The bottom ragged trace was because of the switching regulator noise in the CC supply getting superimposed on the cell voltage, and the fact that instead of the half second per sample, I lowered it to one sample every 10 seconds, so the file would not be too large.
I disconnected the current probe during the 350maCC charge to save the 9V battery in the probe,as we know it was 350ma.