Grid Charger
Grid charger owners and location, as well as some service links for hybrid services
Grid charger code V3.0 manual
Understanding the charging and balancing process
Pack discharger
SOC reset device
Insight Battery pack lifter
Grid charger test adapters
Reprogramming the charger
Installing the Genesis One Universal grid charger in an Insight
Installing the Genesis One Universal grid charger in a First Gen Civic
Harness options
The Universal Grid Charger
MIMA Pack Whack and rebalancing the battery
Battery pack rebalancing?
Building the Solar HV charger/rebalancer
Building the HV probe for the + attachment
failure mode #1 Shorted Cell and the cell Zapper fix?
current indicator
Equilization test #1
fast pack rebalancing 101
Getting better signals
Grid charger/Balancer 1
How do I test the sticks to determine which I need to be replaced
Hybrid Battery Repair
IMA battery smart discharger
Looking better on the second cycle
more tuning of the controller/ Datalogger
Not really rebalanced just changed????
Overnight two stage charger
pack rebalancing test 1
Rebalancing?
Refining the tester
Replacement for 1 Watt LED
Insight Battery pack Solar charger/rebalancer
Subpacks 1-8
Subpack tested first high current run
Subpack tester first test
The HV panels can bend and will shock the S**T out of you
universal dual stage grid charger
What is wrong with the subpacks?
Mikes Insight
EV Insight with a Prius heart
Grid charger Operating Instructions V1.2
Designing a PHEV system for the Civics, Insight 1 and 2 ------------Micro V-Buck PHEV
Doug's V-Boost
Randall's Insight
Paul's Adventures in alternative evergy
Western Washington University X-Prize car
BlueBird1
Finding The Best Hybrid Mix
E-wheel for any vehicle

IMA battery smart discharger

IMA battery smart discharger
smart discharger

We will soon have a nice overnight charger, so the final component required for a fully automatic grid cycler is a discharge monitoring system that can accurately detect when any of the ten 12 cell subpacks that are tapped and appear on the BCM connector drop below 12Vor 1V/cell.
The same circuit will also detect a rapid cell drop off if it happens before the 12 cells get to the 1V/cell level as will happen when a cell reaches depletion before the rest of the cells in the 12 cell string.
Reading the BCM to get the cell drop out detection will be the best way to do the detection, but we are not sure that the BCM reports that information or if it simply terminates assist when the cell dropout is detected.
a totally independent circuit seems like a better solution at this time.
I started the project by mounting all the required components to a large perfboard. The circuit performs well, but one issue came up that I overlooked. The 160 ohm thermistors in series with this circuit will give false voltage readings because of the 160 ohm series resistance. The best solution I can think of so far would be to clip 1A fuses across each of the thermistors, thus making a safe but very low resistance tap to the battery during the testing.
Like all of this type of project, the devils in the details.