What's New | Site Map | Print This Page | Contact Us
Grid charger owners and location
Grid Charger
Grid charger Operating Instructions V1.2
Building a hybrid car grid charger
Installing the Genesis One Universal grid charger in an Insight
Installing the Genesis One Universal grid charger in a First Gen Civic
MIMA Pack Whack and rebalancing the battery
Battery pack rebalancing?
Building the Solar HV charger/rebalancer
Building the HV probe for the + attachment
failure mode #1 Shorted Cell and the cell Zapper fix?
current indicator
Equilization test #1
fast pack rebalancing 101
Getting better signals
Grid charger/Balancer 1
How do I test the sticks to determine which I need to be replaced
Hybrid Battery Repair
IMA battery smart discharger
Looking better on the second cycle
more tuning of the controller/ Datalogger
Not really rebalanced just changed????
Overnight two stage charger
pack rebalancing test 1
Rebalancing?
Refining the tester
Replacement for 1 Watt LED
Insight Battery pack Solar charger/rebalancer
Subpacks 1-8
Subpack tested first high current run
Subpack tester first test
The HV panels can bend and will shock the S**T out of you
universal dual stage grid charger
What is wrong with the subpacks?
Insight Battery pack lifter
Mikes Insight
grid charger instructions V2.0 draft
Grid charger test adapters
Pack discharger
Programming adapter
SOC reset device
Understanding the charging and balancing process
EV Insight with a Prius heart
E-wheel for any vehicle
Designing a PHEV system for the Civics, Insight 1 and 2 ------------Micro V-Buck PHEV
Doug's V-Boost
Finding The Best Hybrid Mix
Randall's Insight
Paul's Adventures in alternative evergy
BlueBird1
Red Light Racing builds the worlds first Diesel Insight
Western Washington University X-Prize car


> Is it too late? I think not if we act now > Projects > MIMA Pack Whack and rebalancing the battery > more tuning of the controller/ Datalogger

more tuning of the controller/ Datalogger

more tuning of the controller/ Datalogger
next subpacks

Traced another subpack with the next generation of the tester.The photo shows 4 screen grabs at different times in the cycle.
Still would like more signal from the temp probes, but this should be good enough. The cell and temp preamplifiers bump up the signal so we have better digital resolution for smoother dataloging.
I will try reading the cell resistance when switching from 36A charge to 6A charge.


> Is it too late? I think not if we act now > Projects > MIMA Pack Whack and rebalancing the battery > more tuning of the controller/ Datalogger
Home - Shopping Cart - New User Registration - MIMA Insight System - Projects - Workshops - Events - Resources - Mikes Blogs - Mikes Tips - What's New